Description
-
ModelKollmorgen
-
Product NamePRD-0046000Z-25
-
Place of OriginIsrael
-
HS Code8504409090
-
Dimensions248mm in length, 136mm in width, 74mm in height
-
Weight1.32kg
-
Operating Temperature-10℃ ~ +65℃
-
Storage Temperature-25℃ ~ +88℃
-
Power Supply24VDC
-
Warranty12 month
-
Product StatusNew and original
-
Product nameMulti-Axis Integrated Servo Drive Controller Module
Backed by abundant in-stock inventory and nearly 20 years of industry experience, our company stands as a leading player in the industrial control sector.We offer an extensive range of industrial control products covering numerous models. Should you have any other requirements, please feel free to contact us, and we will respond to you promptly.
Our main brand:
1.ABB's module cards, touch screens, controllers, etc., such as PP846 touch screen, IGCT starting with 5SHY, PM starting controller, AI, DO starting input/output module, SP starting Bailey module, etc
2.GE's module card CPUs, such as VMIC starter, IS200, IS215, IS400, IS420 series, etc,
3.Emerson's card components and EPRO probes, Westinghouse 1C series, Honeywell CC series, Schneider 140 series, Envision full series, Bentley 3500 series, Rexroth motors and drives, and Foxboro small modules.
Input Voltage
AC Main Input: Single-phase 200–240 VAC @ 50/60 Hz, ±15% allowable voltage variation
DC Bus Voltage: 280–340 VDC
Control Power: Selectable internal DC-link power or external 24 VDC auxiliary power
Analog Signal Voltage: -10 V ~ +10 V (command input), 0–10 V (monitoring output)
I/O Logic Voltage: 24 VDC standard logic level
Output Current
Adjustable continuous phase RMS current: 0.5 A – 8.0 A
Maximum peak output current: 16 A
Open-collector digital output max load current: 20 mA per channel
Relay contact rated current: 1 A (30 VDC / 42 VAC rating)
1. Pre-operation Safety Specifications
Power must be disconnected and capacitors fully discharged for 5 minutes before wiring, disassembly and maintenance; live-line operation is forbidden.
Mount the driver inside well-ventilated cabinets with ambient temperature maintained between 0℃ and 40℃, away from dust, corrosive gas and damp surroundings.
Connector plugging and unplugging are prohibited during running status; secure the motor firmly before power-on commissioning to avoid accidental displacement.
Reliably connect the PE grounding terminal; separate DGND and AGND to lower signal interference.
2. Wiring Installation Procedures
2.1 Main Power Connection
Single-phase 200–240 VAC, 50/60 Hz mains is wired to the power terminal block, with voltage variation limited within ±15%.
Users can switch control auxiliary power between built-in DC-link power and external 24 VDC power through on-board solder jumpers.
This driver is applicable to 2-phase and 5-phase VRDM hybrid stepping motors; select series or parallel winding wiring based on actual current demands.
2.2 Control I/O Connection
Differential RS422 wiring is adopted for high-frequency pulse signals, while single-ended open-collector wiring applies to low-frequency scenarios, with a maximum pulse frequency of 500kHz.
Hardware enable, positive/negative limit, home sensor and fault reset inputs adopt 24 VDC signals, whose trigger logic (active high or active low) is configurable.
Output terminals including ready relay, fault alarm, positioning completion and simulated encoder pulse connect to upper controllers; the 0~10 V analog monitoring port collects real-time motor speed and operating current.
3. Parameter Configuration & Mode Selection
3.1 Current Parameter Setting
Adjust the hardware potentiometer to set phase continuous RMS current within 0.5–8.0 A, and set peak current at 16 A according to motor rated parameters; current settings shall never exceed the motor rated limit.
3.2 Control Mode Switchover
Pulse & Direction Mode: Default positioning control mode suited for PLC positioning tasks, with adjustable microstep resolution up to 50000 steps per revolution.
Analog Control Mode: Realizes closed-loop speed and torque regulation via -10 V~+10 V analog input signals.
Communication Mode: RS485 Modbus RTU bus supports parameter editing and motion instruction transmission; the reserved SynqNet interface realizes multi-axis synchronous control.
3.3 Auxiliary Parameter Calibration
Digital input hardware filter: Adjust debounce time from 0.1 ms to 10 ms to eliminate external signal jitter.
Nonlinear W-type dynamic braking can be activated for quick stop and deceleration control of high-inertia loads.
IxR compensation is enabled by solder jumpers to optimize low-speed motor stability.

4. Power-on Commissioning Steps
Static inspection: Check short-circuit risks, loose wiring and grounding conditions, confirm internal fuses intact.
No-load power-on test: Switch on AC power, verify standby relay closure and no fault alarm indication.
Signal point test: Activate power stage via enable signal, sequentially test limit, homing and reset functions.
No-load jog test: Input low-frequency pulses to check motor rotation direction and running smoothness.
Formal loaded operation: Gradually raise speed and load, monitor analog feedback signals, then confirm and lock stable operating parameters.
5. Standard Daily Operation Rules
Startup flow: Power supply switch-on → standby confirmation → enable signal access → motion command input.
Shutdown flow: Stop motion instructions → disconnect enable signal → cut off power after motor complete standstill.
Continuous operation: Keep driver surface temperature below 75℃; regularly inspect wiring tightness under long-term operation.
6. Common Fault Diagnosis & Solutions
Overcurrent alarm: Caused by motor winding short circuit, wiring errors or excessive current setting; power off to check winding resistance and current parameters.
Overtemperature protection: Resulting from poor heat dissipation and long-time overload; improve ventilation and reduce load current.
Pulse command invalidation: Caused by broken pulse lines, mismatched signal modes or missing enable signal; inspect wiring and enable status.
Motor vibration and abnormal noise: Caused by inappropriate microstep setting and poor low-speed performance; adjust microstep parameters and turn on IxR compensation.
Unresettable faults: Generally hardware damage; check internal fuses and power module integrity.
7. Routine Maintenance Guidelines
Conduct dust removal every 3 to 6 months to guarantee smooth heat dissipation channels.
Unauthorized shell disassembly is forbidden, which will invalidate official warranty.
For long-term shutdown, cut off main power; reserve 5 minutes for capacitor discharge before restart and re-commissioning.
Frequently Asked Questions (FAQ)
1.How fast will you reply to my inquiry?
We process all inquiries efficiently and will respond promptly once we receive your message.
2.Do you carry large inventory of industrial control parts?
We maintain massive ready stock of mainstream automation spare parts to shorten lead times.
3.Can you source discontinued or obsolete PLC & DCS modules?
Absolutely.
We specialize in sourcing hard-to-find, obsolete and out-of-production industrial control components.
4.Do you inspect goods before shipment?
Every product undergoes thorough inspection before packing and dispatch.
5.Can you ship orders worldwide?
We provide global shipping with flexible logistics for urgent and regular orders.
6.What payment methods are available?
We accept multiple secure payment options. Please contact our sales team for detailed terms.