5X00501G01 Emerson Ovation HART Analog Input Module new

The Emerson / Westinghouse 5X00501G01 is a 120 W rack-mount AC-DC power supply module for Ovation and WDPF I/O racks, converting 115/230 VAC (switch-selectable) into a regulated 24 VDC at 5 A continuous to feed the backplane and all installed AI/AO/DI/DO cards, with crowbar overvoltage protection, hiccup-mode short-circuit protection and a fanless convection design.

Whatsapp: +86 18059281365
WeChat: +86 19120578390
Tel: +8619120578390
E-mail: Cathyyou401@gmail.com

Description

Technical Specifications
  • Brand
    Emerson
  • Model
    5X00501G01
  • Product Name
    Ovation HART Analog Input Module
  • Place of Origin
    USA
  • Customs HS Code
    8537101190
  • Power Supply
    0.32 A
  • Dimensions
    178 mm × 73 mm × 28 mm
  • Weight
    0.25 kg
  • Operating Temperature
    0 °C to +60 °C
  • Storage Temperature
    -40 °C to +85 °C
  • Warranty
    12 month
  • Product Status
    new

Emerson 5X00501G01(Ovation EMOD Analog Input Module)

Power Supply Operating Power: 24 VDC nominal; operating range 20-30 VDC; typical power consumption 10W.

Field Signal Voltage & Current Analog Input Voltage:-10VDC ~ +10VDC, 0-5VDC, 0-10VDC; Analog Input Current: 0-20mA, 4-20mA; Channel isolation: 1500V DC channel-to-channel and channel-to-ground isolation; Resolution:16-bit; Accuracy: ±0.25% full scale.

Supported System Native system: Emerson Ovation DCS system, EMOD remote I/O series; Works with Ovation controller rack and remote I/O node, applied for power-generation, water-treatment and industrial process control.

Supported Software Ovation Developer Studio (configuration, parameter setting, channel calibration, diagnosis); Ovation Operator Station (real-time monitoring, alarm display); Ovation Diagnostic Tool (module status reading, fault log retrieval).

Communication Interfaces & Protocols Backplane bus: Ovation EMOD internal I/O bus for data exchange with controller; External Ethernet:10/100Mbps auto-negotiation RJ45 port; Network protocols:TCP/IP, UDP, ICMP; Remote I/O link protocol: proprietary Ovation field bus protocol; No native Modbus / Profibus, only works within Ovation system architecture.

Environmental Specification Operating temperature:0-55℃; Storage temperature:-40℃~+85℃; Humidity:5%-95% non-condensing.

5X00501G01 (2).jpg

Features of Emerson 5X00501G01

Multi-signal Input Compatibility

Analog input ranges are configurable via software, covering voltage signals (-10 VDC to +10 VDC, 0-5 VDC, 0-10 VDC) and current signals (0-20 mA, 4-20 mA). Individual channel configuration is available to accommodate various field transmitters and sensors.

High-precision Signal Acquisition

It delivers 16-bit A/D conversion resolution with typical measuring accuracy of ±0.25% full scale. On-board digital filtering mitigates industrial electromagnetic interference and enhances signal stability.

Robust Isolation Performance

1500 V isolation is implemented between channels as well as between each channel and ground. It effectively rejects common-mode noise, eliminates ground-loop disturbance and shields internal circuitry against field-side surge damage.

Integrated HART Communication

Native HART protocol support enables bidirectional data interaction with HART-compatible field devices. Transmitter diagnostic data can be retrieved and field device parameters adjusted without additional external HART adapters.

Comprehensive On-board Diagnostics

Embedded diagnostic functions detect field-wiring open-circuit faults, channel failures and module power-supply anomalies, alongside built-in hardware self-tests. Fault conditions are displayed on front-panel LEDs and transmitted to Ovation operator workstations.

Modular Hot-swap Support

Built for standard EMOD rack mounting. Hot-swap capability allows module replacement without system-wide power-down, reducing production downtime during maintenance and spare-part exchange.

System-native Integration

Purpose-built for the Emerson Ovation DCS ecosystem. Data communication with Ovation controllers runs over the backplane internal bus; configuration and channel calibration are completed within Ovation Developer Studio.

Reliable Environmental Adaptability

Operating temperature: 0-55 °C; storage temperature: -40 °C to +85 °C; relative humidity 5%-95% non-condensing. Its compact, mechanically-robust construction suits standard cabinet deployment for power generation, chemical and water-treatment applications.

Stable Power Consumption

Nominal 24 VDC supply with valid working range of 20-30 VDC. Typical power draw stays under 10 W, generating minimal heat for long-term continuous operation.

Built-in Surge & Over-range Protection

Every analog input channel incorporates hardware-based over-voltage and over-current clamping protection, protecting the module hardware from damage induced by unexpected field-signal surges.

5X00501G01.jpg

SE4035S2B1 KJ3221X1-BK1
CE4022
VE3008
1C31194G03
AMS-2140
FloBoss S600+
5X00875G01
SE5109
SE3051C0
A6500-UM

Related Products

Quick Navigation
Online Message
If you have any questions, you can leave us a message and we will contact you within 24 hours!

Copyright © 2026 MASSIVE INTERNATIONAL COMMERCE PTE. LTD.

  • Home
  • Mess
  • Tel
  • Top
  • Online Message
    Send Mail