Description
-
BrandEmerson
-
Model5X00489G01
-
Product NameOvation Power Distribution Module
-
Place of OriginUnited States
-
HS Code8538909190
-
Dimensions191 mm × 128 mm × 32 mm
-
Weight0.56 kg
-
Operating Temperature0 °C ~ +55 °C
-
Storage Temperature-40 °C ~ +70 °C
-
Power Supply24VDC
-
Warranty12month
-
Product StatusNew and original
Backed by abundant in-stock inventory and nearly 20 years of industry experience, our company stands as a leading player in the industrial control sector.We offer an extensive range of industrial control products covering numerous models. Should you have any other requirements, please feel free to contact us, and we will respond to you promptly.
Our main brand:
1.ABB's module cards, touch screens, controllers, etc., such as PP846 touch screen, IGCT starting with 5SHY, PM starting controller, AI, DO starting input/output module, SP starting Bailey module, etc
2.GE's module card CPUs, such as VMIC starter, IS200, IS215, IS400, IS420 series, etc,
3.Emerson's card components and EPRO probes, Westinghouse 1C series, Honeywell CC series, Schneider 140 series, Envision full series, Bentley 3500 series, Rexroth motors and drives, and Foxboro small modules.
Power Inputs
Main and auxiliary AC power inputs accept universal alternating current ranging from 85–264 VAC with a frequency bandwidth of 43–67 Hz.
An alternative DC input spanning 90–375 VDC is available for flexible dual power configuration.
The module supports dual redundant main and auxiliary power feeds to realize seamless uninterrupted power auctioneering.
Power Outputs
It features two independent 24 VDC power distribution outputs with an adjustable voltage range of 23.5 VDC ~ 28.5 VDC, factory preset to 24.5 VDC ±1%.
Each channel delivers a maximum rated output current of 20 A, and the overall maximum output power reaches 480 W.
The output ripple is controlled below 100 mVpp under full-load operating conditions.
Regulated power is provided to Ovation controller chassis, I/O modules, field instrument loops as well as contact wetting circuits.
Status Signal Inputs
External power failure contact inputs monitor the operational status of upstream power supplies.
Terminal ports receive dry contact auxiliary fault signals transmitted from external power equipment.
Status Outputs
Dry contact alarm outputs trigger upon module faults, overvoltage, undervoltage and overcurrent protection activations.
Front-panel LED indicators visually display power availability, fault alerts and active output status for on-site inspection.
Communication & Monitoring Interface
An internal monitoring bus enables transmission of operational parameters and fault diagnostic information to Ovation system controllers.
Supplementary Notes
The 5X00489G01 serves as an Ovation power distribution module rather than a signal I/O module. It is not equipped with analog or digital field signal input channels. All output terminals are designated for power distribution instead of control signal transmission. Adopting a fanless passive cooling structure, the module is capable of stable long-term continuous operation within industrial environments.

Pre-commissioning Safety & Visual Inspection
Comply with lockout-tagout safety procedures prior to all wiring inspections and power-on tests.
Visually examine the module for physical damage, burnt components or thermally deformed terminals.
Ensure the module is firmly installed inside the Ovation cabinet with sufficient ventilation, and keep unobstructed airflow surrounding its fanless passive cooling structure.
Cross-check all input and output wiring against construction drawings. Confirm terminals are securely tightened without loose wire strands, reversed polarity or potential short-circuit hazards.
Physically separate high-voltage AC input cables and low-voltage 24 VDC output cables to mitigate electromagnetic interference.
Validate that fuses fitted for main and auxiliary power feed circuits conform to design specifications.
Wiring Continuity & Pre-power Measurement
Use a digital multimeter to measure insulation resistance between live conductors and protective earth.
Inspect main and auxiliary power input terminals to rule out short circuits among phase, neutral and ground connections.
Confirm all 24 VDC distribution output terminals remain open-circuited before connecting field loads.
Examine external dry-contact wiring for power failure monitoring inputs and module alarm status outputs.
Verify wiring integrity of the internal monitoring bus that facilitates communication between the 5X00489G01 and Ovation controller modules.
Dual Redundant Input Power Test
Energize the main AC/DC input source first. Measure the input voltage and confirm it complies with the rated range: 85–264 VAC or 90–375 VDC.
Observe the front-panel power indicator to confirm smooth module initialization and stable operating status.
Alternate power supply between main and auxiliary feeds separately to verify the automatic power auctioneering function.
Simulate loss of the main power source and confirm seamless transfer to the auxiliary supply without disruption to the 24 VDC output.
Ensure no unnecessary power failure alarms are generated during normal redundant switching operations.
24 VDC Output Performance Verification
Measure no-load output voltage and confirm the value falls within the adjustable range of 23.5 VDC ~ 28.5 VDC (factory preset at 24.5 VDC ±1%).
Connect field loads incrementally while monitoring output voltage stability. Guarantee the load current never exceeds the maximum rating of 20 A per channel and the overall power limit of 480 W.
Utilize an oscilloscope to test output ripple, which shall stay below 100 mVpp under full-load operating conditions.
Conduct independent tests on both output channels to verify reliable operation without mutual interference.
Protection Function Commissioning
Gradually increase the load to simulate an overcurrent condition. Confirm the module shuts down outputs appropriately and triggers fault alarms once protection activates.
Verify overvoltage and undervoltage protection thresholds, ensuring protective actions engage when output voltage drifts outside allowable boundaries.
Remove overload conditions and confirm the module resumes normal operation after power cycling or automatic recovery in accordance with hardware specifications.
Confirm transient signal fluctuations will not trigger undesired protection tripping and accidental shutdown of critical Ovation I/O loads.
Status Signal & Alarm Contact Test
Inject a simulated upstream power failure signal and confirm the module accurately captures the external fault input.
Check that dry contact alarm outputs are actuated upon overvoltage, undervoltage, overcurrent or internal module faults.
Test contact continuity with a multimeter and ensure contacts operate within specified electrical ratings.
Validate front-panel LED indicators precisely display power availability, active output status and fault conditions.
Communication & Ovation System Integration Test
Establish communication between the module and the Ovation system controller over the internal monitoring bus.
Launch Ovation Developer Studio to retrieve real-time module data, including input voltage, output voltage, load current and fault codes.
Manually trigger test faults and confirm all alarm events are transmitted to the Ovation operator station without delay.
Ensure fault timestamps and diagnostic information can be recorded within system event logs for subsequent troubleshooting.
Load Onboarding & Continuous Running Test
Switch on all official field loads progressively; avoid simultaneous full-load energization to suppress damaging inrush current.
Monitor module temperature, output voltage and load current over a minimum continuous operating period.
Watch out for intermittent voltage drops, abnormal overheating and spurious fault alarms during steady-state operation.
Document all measured operating parameters as baseline reference data for regular maintenance comparison in the future.
Post-commissioning Documentation & Handover
Archive all test records containing voltage readings, load current data and protection test results.
Apply clear identification labels to all terminal circuits for convenient maintenance.
Brief on-site operating personnel regarding normal indicator states and typical responses to fault alarms.
Complete the commissioning acceptance form and attach all measured data to official project archives.

Frequently Asked Questions (FAQ)
1.How fast will you reply to my inquiry?
We process all inquiries efficiently and will respond promptly once we receive your message.
2.Do you carry large inventory of industrial control parts?
We maintain massive ready stock of mainstream automation spare parts to shorten lead times.
3.Can you source discontinued or obsolete PLC & DCS modules?
Absolutely.
We specialize in sourcing hard-to-find, obsolete and out-of-production industrial control components.
4.Do you inspect goods before shipment?
Every product undergoes thorough inspection before packing and dispatch.
5.Can you ship orders worldwide?
We provide global shipping with flexible logistics for urgent and regular orders.
6.What payment methods are available?
We accept multiple secure payment options. Please contact our sales team for detailed terms