Description
-
BrandABB
-
ModelUC D240 A01
-
Product NameConverter Module
-
Place of OriginFinland
-
HS Code8538909190
-
Dimensions180 mm × 150 mm × 60 mm
-
Weight1.2 kg
-
Operating Temperature-20 °C ~ +60 °C
-
Storage Temperature-40 °C ~ +85 °C
-
Part Number3BHE022287R0001
-
Warranty12 month
-
Product StatusNew and original
Backed by abundant in-stock inventory and nearly 20 years of industry experience, our company stands as a leading player in the industrial control sector.We offer an extensive range of industrial control products covering numerous models. Should you have any other requirements, please feel free to contact us, and we will respond to you promptly.
Our main brand:
1.ABB's module cards, touch screens, controllers, etc., such as PP846 touch screen, IGCT starting with 5SHY, PM starting controller, AI, DO starting input/output module, SP starting Bailey module, etc
2.GE's module card CPUs, such as VMIC starter, IS200, IS215, IS400, IS420 series, etc,
3.Emerson's card components and EPRO probes, Westinghouse 1C series, Honeywell CC series, Schneider 140 series, Envision full series, Bentley 3500 series, Rexroth motors and drives, and Foxboro small modules.
Power Supply
Nominal supply voltage: 24 V DC.
Typical operating current reaches 1.3 A under regular working conditions, while the maximum operating current is limited to 1.6 A.
The maximum power consumption of the module is 38.4 W.
This unit receives power via the system backplane and is designed for deployment within the UNITROL 6080 excitation control system.
Signal Interface
Supported analog signal levels cover 0–10 V voltage signals and standard 0/4–20 mA current signals for industrial measurement and control transmission.
The digital interface adopts a 24 V DC logic standard.
For digital input channels, low-level threshold is ≤5 V DC, and high-level threshold is ≥18 V DC to guarantee stable identification of switching status in harsh industrial environments.

Pre-installation Safety Preparation
Disconnect all power sources of the UNITROL 6080 excitation control cabinet and verify zero voltage across the rack backplane. Wear an anti-static wrist strap to prevent electrostatic discharge damage to onboard electronic components. Visually examine the module for any damage incurred during transit, and confirm the part number corresponds to 3BHE022287R0001 UC D240 A01.
Rack Position Confirmation
Locate the assigned slot on the UNITROL 6080 system backplane. Remove dust and debris within the slot to ensure secure electrical contact with the backplane. Inspect backplane bus terminals to rule out potential short-circuit hazards.
Module Mechanical Insertion
Align the connector of the UC D240 A01 circuit board with the backplane socket. Slide the module horizontally and steadily into the slot until full engagement of the backplane connector. Secure the module to the rack by fastening the mounting screws on both sides of the front panel with proper torque. Avoid excessive force to prevent bending or damage to connector pins.
Field Wiring Connection
Arrange signal and power cables in accordance with terminal assignment specifications. Terminate analog signals (0–10 V, 0/4–20 mA) and 24 V DC digital input circuits. Physically separate power and signal cables to mitigate electromagnetic interference. Deploy shielded twisted-pair cables for analog wiring with single-point shield grounding. Carefully verify wiring polarity to eliminate reverse connection risks.
Wiring Inspection
Recheck the tightness of all terminals and ensure there are no loose connections, open circuits or short circuits. Confirm digital input signals comply with defined threshold criteria: low level ≤5 V DC, high level ≥18 V DC. Ensure reliable protective earthing for both the cabinet and the module.
Power-on Pre-check
Validate proper module seating and completion of all wiring work. Maintain the cabinet door open for on-site observation during startup. Re-energize the system’s 24 V DC control power supply. Monitor whether the module power indicator illuminates normally, and watch out for unusual overheating or strange odors.
Communication & Function Verification
Configure system parameters using the upper-level monitoring software. Establish data communication links between the UC D240 A01 and other UNITROL 6080 modules. Perform tests on analog signal sampling and digital signal detection functions to validate accurate measured values and status feedback.
Final Installation Completion
Shut the cabinet door only after successful stable operation testing. Document installation date, rack slot location and relevant parameter configurations for future maintenance and troubleshooting.

Frequently Asked Questions (FAQ)
1.How fast will you reply to my inquiry?
We process all inquiries efficiently and will respond promptly once we receive your message.
2.Do you carry large inventory of industrial control parts?
We maintain massive ready stock of mainstream automation spare parts to shorten lead times.
3.Can you source discontinued or obsolete PLC & DCS modules?
Absolutely.
We specialize in sourcing hard-to-find, obsolete and out-of-production industrial control components.
4.Do you inspect goods before shipment?
Every product undergoes thorough inspection before packing and dispatch.
5.Can you ship orders worldwide?
We provide global shipping with flexible logistics for urgent and regular orders.
6.What payment methods are available?
We accept multiple secure payment options. Please contact our sales team for detailed terms