Description
-
BrandHima
-
ModelF3237
-
Product Name8‑Channel Safety‑Related NAMUR Digital Input Module
-
Place of OriginGermany
-
HS Code8537101190
-
Dimensions128 mm × 100 mm × 22 mm
-
Weight0.14 kg
-
Operating Temperature-20℃ to +60℃
-
Storage Temperature-40℃ to +85℃
-
Power Supply24 VDC
-
Warranty12 month
-
Product Statusnew and original
HIMA F3237 Input / Output
Model: F3237
Module Type: 8-channel safety-grade NAMUR digital input module without physical field output channels
Input
Channel quantity: 8 galvanically-isolated input channels
Signal standard: NAMUR per DIN 19234
Logic-0 current: 0.35 mA … 1.2 mA
Logic-1 current: 2.1 mA … 6.0 mA
Wire-break detection threshold: ≤ 0.28 mA
Short-circuit detection threshold: ≥ 6.5 mA
Maximum per-channel line impedance: ≤ 50 Ω
Maximum cable length: 1000 m (0.5 mm² conductor)
Internal shunt resistor: 681 Ω, 1 %, 0.25 W
Typical response time: 10 ms
Output
No field-side physical outputs.
Internal backplane communication output: transfers input status and safety diagnostic data to the HIMA rack CPU over the system backplane bus.
Module Power Consumption
5 VDC: 90 mA
24 VDC: 170 mA
Diagnostic Features
Per-channel continuous monitoring for wire breakage and short-circuit faults
Built-in automatic tests including channel crosstalk check, walking-0 test and input-circuit self-diagnosis
SIL 3 certified for safety-instrumented system applications

HIMA F3237 Application Scenarios
Typical Field Device Connections
NAMUR proximity switches
NAMUR limit switches and valve position feedback sensors
NAMUR emergency-stop push-buttons
NAMUR safety interlock switches
Relay outputs from NAMUR flame and gas detectors
Industry and System-Level Applications
ESD Emergency Shutdown System (Oil & Gas, Petrochemical)
Gathers safety discrete signals for well-head assemblies, process units and offshore installations. It monitors emergency-stop commands, valve position feedback and safety switch states to initiate safe process shutdown when hazardous conditions arise.
F&G Fire and Gas Protection System
Receives status feedback from NAMUR-type flame, combustible-gas and toxic-gas detectors, and executes fire-gas interlock logic within the safety instrumented system.
BMS Burner Management System (Power Plants, Refinery Heaters)
Captures flame-detector relay signals and safety interlock switch status to deliver safety supervision for furnaces and boilers.
Chemical Process Safety Interlock
Monitors reactor safety limit switches, tank high- / low-level NAMUR switches and local emergency-stop units. It detects wire-break and short-circuit faults within safety instrumented loops.
Safety Protection for Critical Rotating Machinery
Interfaces safety interlock switches of compressors, turbines and large-scale process equipment to realize safety-guard interlock functions.
Safety-Oriented Factory Automation
Serves high-risk manufacturing facilities for safety-door interlocks and safety limit switches, suitable for SIL 3 safety instrumented loops.