Description
-
BrandABB
-
ModelHVC-02
-
Product NameHigh Voltage Controller
-
Dimensions203 mm × 172 mm × 51 mm
-
Weight0.82 kg net weight
-
Place of OriginSweden
-
HS Code85176200
-
Operating Temperature‑10 °C to +50 °C
-
Storage Temperature‑35°C to +75 °C
-
Manufacturing part number3HNA029043-001
-
Warranty12 month
-
Statusnew brand
ABB HVC-02, 3HNA029043-001
High-Voltage Controller for Robot Electrostatic Painting
Supported Systems
Robot Controller: ABB IRC5 / IRC5P paint robot controller
RobotWare: V5.13 and above, PaintControl license option is mandatory
Communication bus: Internal CAN-bus for robot system communication
Compatible robot models: IRB5500, IRB52, IRB54 painting robots
External interface: 24V DC discrete I/O for connection with site PLC system
Supported Software
RobotStudio: Supports offline configuration, parameter downloading and fault diagnosis
FlexPendant: Real-time parameter tuning, status observation and fault code reading on site
PaintControl RAPID package: Dedicated RAPID commands for high-voltage activation, voltage parameter setup and fault disposal
Input Signals (24V DC)
HV_Enable: High-voltage enable command signal transmitted from IRC5 controller
HV_Reset: Signal for fault condition reset
External_Interlock: Inhibit signal from external safety interlock device
HV_Set_Analog_In: Analog input for target high-voltage reference setting
24V DC power and GND power supply input
Output Signals (24V DC)
HV_Ready: Module power-on completion and operational readiness status
HV_Active: Feedback signal indicating high-voltage output is in operation
HV_Fault: Collective alarm output for module abnormal status
HV_Overcurrent: Output triggered by over-current protection
HV_Overvoltage: Output triggered by over-voltage protection
HV_Measure_Analog_Out: Analog output reflecting real-time high-voltage measured feedback value

ABB HVC-02, 3HNA029043-001 Wiring Method
General Wiring Requirements
Complete all wiring work with power disconnected. Shielded cables shall be applied for analog signals and CAN-bus communication. Cable shield should be single-ended grounded to the module housing.
Power Wiring
Link 24V DC positive pole to the module’s 24V terminal and 0V/GND to the GND terminal. Polarity must be correct, as reversed polarity will cause permanent module damage. Attach the module PE housing terminal to protective earth ground.
CAN-Bus Communication Wiring
Adopt robot-specific internal CAN-bus cable and plug into the dedicated CAN connector of HVC-02. Termination resistor is activated on IRC5 controller side, and no additional termination resistor is required for HVC-02. This bus handles data interaction between HVC-02 and IRC5 robot controller.
Digital Input Wiring (24V DC, PNP, supplied by IRC5 controller)
HV_Enable: Wire to IRC5 digital output channel; high logic level activates HVC-02 high-voltage output
HV_Reset: Wire to IRC5 digital output channel; fault reset is triggered by rising edge signal
External_Interlock: Connect to external safety interlock contact; high level releases interlock while low level blocks high-voltage output
Ground references for all input signals shall be tied to the 0V reference point of robot controller.
Analog Input Wiring
HV_Set_Analog_In: 0-10V analog reference signal sent from IRC5 for target high-voltage adjustment. Connect signal negative terminal to analog GND, and deploy shielded twisted-pair cable.
Digital Output Wiring (24V DC open-collector, external 24V DC pull-up is required)
HV_Ready: Feedback signal for module operational readiness
HV_Active: Feedback signal indicating high-voltage output is working
HV_Fault: Collective alarm signal for module malfunctions
HV_Overcurrent: Alarm output for over-current protection activation
HV_Overvoltage: Alarm output for over-voltage protection activation
For each output channel, install the load between 24V power supply and output terminal. The shared 0V reference shall be consistent with robot system ground.
Analog Output Wiring
HV_Measure_Analog_Out: 0-10V analog feedback reflecting real high-voltage measured value. Connect to IRC5 analog input channel, link signal negative to analog GND and use shielded twisted-pair cable.
High-Voltage Output Wiring
Connect the high-voltage terminal of HVC-02 to high-voltage cable of electrostatic bell or spray gun. Maintain adequate creepage distance for high-voltage circuits. Insulation and clearance specifications shall fully comply with ABB painting robot installation manuals.
Wiring Precautions
Route high-voltage cables separately from low-voltage signal cables to prevent electromagnetic interference
Fasten all connector screws according to required torque value
Double-check full wiring before power-on commissioning
Internal wiring of HVC-02 module shall not be altered arbitrarily

GDB021BE
Unitrol 1020
698B275U01
SM810K01
BC810K02
PP886
PBA800
RED615